12.2. SPIRE Photometer AOT

Selecting "SPIRE Photometer" from the "Observation" menu gives the AOT for photometry with SPIRE (SPIRE Observers' Manual). This AOT is used to make photometric images in 3 bands "centred" at 250, 350 and 500 µm with a resolution of ~3. The first step is to define a target, see Section 6.3. Under "instrument setting" on the screen you see "Source Type", "On-source Integration Time", "Source Flux Estimates" and "Observation Estimates" parts which are briefly described in the following sections and then in more detail for the specific "Source Type" selections.

The SPIRE Photometer AOT, as it appears on first opening.

Figure 12.1. The SPIRE Photometer AOT, as it appears on first opening.

Source Type

Three modes are permitted:

See the SPIRE Observers' Manual for details of the AOTs. You should select the option appropriate to the required source type. Depending on the selection additional menus may appear. For point sources and small maps you can define chopper avoidance constraints. For large maps a panel appears that allows you to enter the parameters that define the map (size, speed, map orientation constraints etc.). The AOT screen also presents a box for entering the "Repetition factor" and a button to bring up a panel for entering source flux estimates. The "Repetition factor" controls the on-source integration time, as the SPIRE AORs consist of basic units which can be repeated to increase the time spent observing. The "Repetition factor" and source type selection are used to make a time estimate for the duration of the observation. If estimates for the source fluxes are also entered then signal to noise estimates will be reported back in the time estimation results.

Repetition factor

Here you should enter the number of repetitions of the basic observation that you would like to use. This will be used by the observation estimator to give you the estimated time required to carry out the observation. You can change the factor entered and repeat the estimate; this is particularly useful when one wants to obtain a required signal to noise ratio.

Source Flux Estimates

This button pops-up a panel in which you can enter source flux estimates and also gives you the possibility to switch to bright source setting of the instrument (see the SPIRE Observers' Manual for more details on this). The source flux estimates are not necessary for the time estimation, however if values are filled in the expected S/N of the observation is shown. Further details of the "Source Flux Estimates" panel are given in the sections below.

12.2.1. Point Source

A Point Source observation is made by a 7-point jiggle pattern around a co-aligned pixel, giving data simultaneously in all three bands for this pixel. Chopping and nodding are also performed (see the SPIRE Observers' Manual for details). To select this source type the radio button should be selected as shown in Figure 12.2. For this selection the Chop Avoidance panel is displayed.

The SPIRE Photometer AOT with point source selected. Note the "Chop Avoidance" panel.

Figure 12.2. The SPIRE Photometer AOT with point source selected. Note the "Chop Avoidance" panel.

12.2.1.1. Chop Avoidance

When Point Source is selected the Chop Avoidance can be used. You can use this to avoid chopping and nodding onto nearby bright sources. Initially the boxes cannot be edited. The number of chop avoidances to be defined should be selected from the pull down menu which gives you the option to select up to 3.

[Warning]Warning

Chopper avoidances should only be defined if really necessary, as each one reduces the visibility window for your source. Putting too strong constraint may make it impossible to schedule the observation, or even make the source unobservable for Herschel. A chopping constraint is incompatible with a fixed time observation.

On selection of 1, 2 or 3 the following warning is presented in Figure 12.3:

The Chopper Avoidance warning

Figure 12.3. The Chopper Avoidance warning

Once the warning has been understood and dismissed by pressing "OK", the number of "Avoidance From and To" boxes corresponding to the number selected are ungreyed. These can be edited, so that the angles for avoidance can be entered. The angles are in degrees from north, through east and can be entered with a precision of one degree. To avoid a source located to the north one should remember to enter a number lower than 360 in the "From" box and one greater than 0 in the "To" box. As chopping and nodding occur to either side of the source then the range of angles ± 180 are also avoided. See the SPIRE Observers' Manual for examples of how to work out the chop avoidance angles using HSpot visualisation.

It is very important to check the visibility by pressing the "Visibility..." button which will report the visibility periods for the source with the entered constraints. In such a way you can control and change the constraints if the visibility window shrinks too much or if the constraints makes the source unobservable for Herschel.

12.2.1.2. Repetition factor

The required number of repetitions of the basic observation should be put here. The Repetitions are defined in the SPIRE Observers' Manual.

12.2.1.3. Source Flux Estimates

The table allows estimated source fluxes to be introduced to give the expected S/N (see Figure 12.4). The sensitivity results assume that a point source has zero background. The source details that can be entered are the estimated point source flux density in mJy for zero to three of the SPIRE bands. If no value is given for a band the corresponding S/N is not reported back. The time estimation will return the corresponding S/N, as well as the original values entered, if applicable.

In the same window you have control over the instrument settings when you are going to observe very bright sources. As the message above the "Use Bright Source Mode" selector says, you should check if your source falls in the bright source applicable flux limits as described in the SPIRE Observers' Manual, before switching on this mode.

Source flux estimates panel for point sources.

Figure 12.4. Source flux estimates panel for point sources.

12.2.1.4. Observation Time Estimation

On pressing the "Observation Estimation" button the duration of the observation is estimated and a panel pops up with the results (Figure 12.5).

Time estimation panel for Point Source observation.

Figure 12.5. Time estimation panel for Point Source observation.

At the top of the panel there is a table with one entry per wavelength band with columns for:

  • Flux density (mJy): the number entered in the source flux estimates table is displayed.

  • S/N: a result is displayed if estimated source flux densities were given. Note that maximum achievable S/N is 200.

  • 1-σ noise (mJy): always calculated and displayed.

After this, the break down into observing time and overheads is displayed:
  • On-source time per repetition (s): the time of the basic observation unit.

  • Number of repetitions: the repetition factor as entered by the user.

  • Total on-source integration time (s): (On-source time per repetition)*(Number of repetitions)

  • Instrument and observation overheads (s): the calibration time and dead time associated with the observation.

  • Observatory overheads (s): the slew overhead implicit in every observation (3 minutes normally, 10 if the observation is constrained).

  • Total time (s): The total time of the observation, equalling the sum of the following contributions: Total on-source integration time, the Instrument and observation overheads and the Observatory overheads.

This is followed by a note to explain how to increase the observation time.

Time Estimation Details Button

Message level 1 indicates how the observation is built up. Message level 3 gives parameters of the observation such as the number of nod cycles and the nod/chop throw. More details on what is contained in the detailed messages are given in the SPIRE Observers' Manual.

12.2.1.5. Confusion Noise Estimation Summary

The breakdown of calculated confusion noise is given in a table at the bottom of the "SPIRE Time Estimation Summary" screen. It indicates the confusion noise specific for the AOR configuration (see the Herschel Confusion Noise Estimator Science Implementation Document for details). When the window pops up this table is empty, in order to get a confusion noise estimation the "Update confusion noise estimates" button has to be pushed.

12.2.2. Small Map

A Small Map observation is made using a 64-point jiggle pattern to give a fully filled map with simultaneous data in all three bands. Chopping with the beam steering mirror and nodding with the telescope are also performed (see the SPIRE Observers' Manual). The Small Map option is the default that is selected when one opens a new SPIRE Photometer AOT as is shown in Figure 12.1.

12.2.2.1. Repetition factor

The required number of repetitions of the basic observation should be put here. The Repetitions are defined in the SPIRE Observers' Manual.

12.2.2.2. Source Flux Estimates

Pressing the Source Flux Estimates buttons brings up a table that allows estimated source fluxes to be introduced to give the expected S/N (see Figure 12.6). The point source flux density and the extended source surface brightness are treated independently by the sensitivity calculations; the sensitivity results assume that a point source has zero background and that an extended source is not associated with any point sources. The source details that can be entered are the estimated point source flux density in mJy and/or the extended source surface brightness in MJy/sr. If no value is given for a band the corresponding S/N is not reported back. The time estimation will return the corresponding S/N, as well as the original values entered, if applicable.

In the same window you have control over the instrument settings when you are going to observe very bright sources. As the message above the "Use Bright Source Mode" selector says, you should check if your source falls in the bright source applicable flux limits as described in the SPIRE Observers' Manual, before switching on this mode.

Source flux estimates panel for Small Map Source types.

Figure 12.6. Source flux estimates panel for Small Map Source types.

12.2.2.3. Observation Time Estimation

On pressing the "Observation Est..." button the estimated duration of the observation is displayed and a pop-up gives the results (see Figure 12.7 for the appearance without source flux estimates and Figure 12.8 with the estimates as given in Figure 12.6). At the top of the panel there is a table with one entry per wavelength band with columns for:

  • Point source flux density (mJy): a number is displayed which mirrors the corresponding estimated point source flux density field (if filled in).

  • Point source S/N: a number is displayed if the corresponding estimated point source flux density field was filled in. Note that maximum achievable S/N is 200.

  • Point source 1-σ noise (mJy): always displayed.

  • Extended source surface brightness (MJy/sr): a number is displayed if the corresponding estimated extended source surface brightness field was filled in.

  • Extended source S/N: a number is displayed if the corresponding estimated extended source surface brightness field was filled in. Note that maximum achievable S/N is 200.

  • Extended source 1-σ noise (MJy/sr): always displayed.

After this, the break down into observing time and overheads is displayed:

  • On-source time per repetition (s): the time of the basic observation unit.

  • Number of repetitions: the repetition factor as entered by the user.

  • Total on-source integration time (s): (On-source time per repetition)*(Number of repetitions)

  • Instrument and observation overheads (s): the calibration time and dead time associated with the observation.

  • Observatory overheads (s): the slew overhead implicit in every observation (3 minutes normally, 10 if the observation is constrained).

  • Total time (s): The total time of the observation, equalling the sum of the following contributions: Total on-source integration time, the Instrument and observation overheads and the Observatory overheads.

This is followed by a note to explain how to increase the observation time.

Small Map time estimation results.

Figure 12.7. Small Map time estimation results.

Small Map time estimation results with some source flux estimates previously entered.

Figure 12.8. Small Map time estimation results with some source flux estimates previously entered.

12.2.2.4. Time Estimation Details Button

Message level 1 indicates how the observation is built up. Message level 3 gives parameters of the observation such as the number of nod cycles and the nod/chop throw.

12.2.2.5. Confusion Noise Estimation Summary

The breakdown of calculated confusion noise is given in a table at the bottom of the "SPIRE Time Estimation Summary" screen. It indicates the confusion noise specific for the AOR configuration (see the Herschel Confusion Noise Estimator Science Implementation Document for details). When the window pops up this table is empty, in order to get a confusion noise estimation the "Update confusion noise estimates" button has to be pushed.

12.2.3. Large Map

A Large Map is made by scanning the telescope to move the arrays over the required field of view. The telescope is scanned along lines at one of two speeds hence, to increase integration time for a certain speed the scan is repeated (see the SPIRE Observers' Manual for more details). The panel with the Large Map selected as the source type is shown in Figure 12.9.

The SPIRE Photometer AOT with Large Map selected and map sizes filled in.

Figure 12.9. The SPIRE Photometer AOT with Large Map selected and map sizes filled in.

12.2.3.1. Large Map Parameters

When a "Large Map" is selected the "Large Map Parameters" panel appears. The required map size should be entered, in arcminutes, in "Length" (the distance, along the first scan direction, of the area to be mapped) and "Height" (the distance to be covered in the direction perpendicular to the first scan). The speed at which the telescope scans can be selected as either "Nominal" (the default, currently 30"/s) or "Fast" (currently 60"/s). When the "Scan Direction" is set to either "Scan Angle A" or "Scan Angle B", "Length" can be in the range of 4.0 - 1186.0 arcminutes and the "Height" between 0.0 and 240.0 arcminutes, when the "Scan Direction" is set to "Scan Angles A and B" then "Length" can be between 4.0 and 226.0 arcmin and the "Height" between 0.0 and 226.0 arcmin. The map centre Y and Z offsets can be used to define a map centre that is offset compared with the coordinates of the target of the observation. See the SPIRE Observers' Manual for uses of this and example observations.

Orientation

Maps are made at a specific angles (A=42.4 degrees, B=-42.4 degrees) to the SPIRE arrays' short axis (Z). As the arrays rotate with time against to the sky one can choose to restrict the amount of rotation on the sky by specifying a range of angles. This equates to a period within which the observation can be scheduled hence the following warning is given with the option "Array with Sky Constraint" is selected:

[Warning]Warning

"Specifying the map orientation constraint places restrictions on when the observation can be scheduled. The observatory overhead for this observation will be 600s. These constraints might reduce the chance that your observation will be carried out, especially targets at low ecliptic latitudes could be inaccessible for certain chopper or map angles. Are you sure that this constraint is essential? (You may check your observation's footprint orientations by clicking in the HSpot menu: Overlays -> AORs on current image... see the SPIRE Observers' Manual for examples) "

Once the warning has been understood and dismissed by pressing OK, the "Angle From" and "Angle To" values, between which the scan leg length dimension of the map should lay, can be given in degrees East of North can be entered. See the SPIRE Observers' Manual for a worked example.

The visibility should always be checked after map orientation constraint is set.

12.2.3.2. Repetition factor

The required number of repetitions of the basic observation should be put here. The Repetitions are defined in the SPIRE Observers' Manual.

12.2.3.3. Source Flux Estimates

Pressing the Source Flux Estimates buttons brings up a table that allows estimated source fluxes to be introduced to give the expected S/N (see Figure 12.6). The Point source flux density and the extended source surface brightness are treated independently by the sensitivity calculations; the sensitivity results assume that a point source has zero background and that an extended source is not associated with any point sources. The source details that can be entered are the estimated point source flux density in mJy and/or the extended source surface brightness in MJy/sr. If no value is given for a band the corresponding S/N is not reported back. The time estimation will return the corresponding S/N, as well as the original values entered, if applicable.

In the same window you have control over the instrument settings when you are going to observe very bright sources. As the message above the "Use Bright Source Mode" selector says, you should check if your source falls in the bright source applicable flux limits as described in the SPIRE Observers' Manual, before switching on this mode.

12.2.3.4. Observation Time Estimation

On pressing the "Observation Est..." button the duration of the observation is estimated (calculated) and a pop-up displays the results (see Figure 12.10 for the screen when no flux estimates have been given, and Figure 12.11 using estimates given in Figure 12.6).

Large Map (200x100 arcmin) time estimation where no source flux estimates have been provided

Figure 12.10. Large Map (200x100 arcmin) time estimation where no source flux estimates have been provided

Large Map (200x100 arcmin) time estimation where source flux estimates have been provided

Figure 12.11. Large Map (200x100 arcmin) time estimation where source flux estimates have been provided

An example of a table. There is one entry per wavelength band. The columns are:

  • Point source flux density (mJy): a number is displayed that mirrors the corresponding estimated point source flux density field (if filled in).

  • Point source S/N: a number is displayed if the corresponding estimated point source flux density field was filled in. Note that maximum achievable S/N is 200.

  • Point source 1-σ noise (mJy): always displayed.

  • Extended source surface brightness (MJy/sr): a number is displayed if the corresponding estimated extended source surface brightness field was filled in.

  • Extended source S/N: a number is displayed if the corresponding estimated extended source surface brightness field was filled in. Note that maximum achievable S/N is 200.

  • Extended source 1-σ noise (MJy/sr): always displayed.

Next, the break down into observing time and overheads is displayed:

  • On-source integration time per map repetition (s): the time it takes to make one coverage of the map.

  • Number of map repetitions: the repetition factor as entered by the user.

  • Total on-source integration time (s): (On-source integration time per map repetition)*(Number of map repetitions)

  • Instrument and observation overheads (s): the calibration time and dead time associated with the observation.

  • Observatory overheads (s): the slew overhead implicit in every observation (3 minutes normally, 10 if the observation is constrained).

  • Total time (s): The total time of the observation, equalling the sum of the following contributions: Total on-source integration time, the Instrument and observation overheads and the Observatory overheads.

This is followed by a note to explain how to increase the observation time.

Time Estimation Details Button

Message level 1 indicates how the observation is built up. Message level 3 gives parameters of the observation such as the angle at which the array is scanned, the total scan length (increased from your input to get as even coverage as possible over requested area), and the number of scans needed to cover the area.

Confusion Noise Estimation Summary

The breakdown of calculated confusion noise is given in a table at the bottom of the "SPIRE Time Estimation Summary" screen. It indicates the confusion noise specific for the AOR configuration (see the Herschel Confusion Noise Estimator Science Implementation Document for details). When the window pops up this table is empty, in order to get a confusion noise estimation the "Update confusion noise estimates" button has to be pushed.